BZQYR - MANGANESE DIOXIDE LITHIUM PRIMARY BATTERIES

  • MSDS: BZQYR
  • Manufacturer: SANYO ENERGY USA CORP
  • Product Name: MANGANESE DIOXIDE LITHIUM PRIMARY BATTERIES
  • National Stock Number: 6135-01-205-5965
Product Identification

Product ID:MANGANESE DIOXIDE LITHIUM PRIMARY BATTERIES
MSDS Date:01/01/1999
FSC:6135
NIIN:01-205-5965
MSDS Number: BZQYR

Responsible Party
SANYO ENERGY USA CORP
2001 SANYO AVE
SAN DIEGO, CA 92173
US

Emergency Phone: 619-661-6620

Info Phone: 619-661-6620

Cage: 00JU0

Contractor
SANYO ENERGY(U.S.A.) CORP.
SAN DIEGO, CA 92173 US

Telephone: 619-661-6620

Cage: 00JU0

Ingredients

MANGANESE DIOXIDE

CAS: 1313-13-9

RTECS: OP0350000

OSHA PEL 5 MG MN/M3 CEILING

ACGIH TLV: 5 MG MN/M3


LITHIUM

CAS: 7439-93-2

RTECS: OJ5540000


PROPYLENE CARBONATE (PC)

CAS: 108-32-7

RTECS: FF9650000


DIMETHOXYETHANE (DME)

CAS: 110-71-4

RTECS: KI1451000


LITHIUM PERCHLORATE

CAS: 7791-03-9

Fraction By Weight: UNKNOW

Hazards

Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:THESE CHEMICALS ARE CONTAINED IN A
SEALED CAN. RISK OF EXPOSURE OCCURS ONLY IF THE BATTERY IS
MECHANICALLY OR ELECTRICALLY ABUSED. THE MOST LIKELY RISK IS ACUTE
EXPOSURE WHEN A CELL VENTS. DME IS BELI EVED TO BE SLIGHTLY TO
MODERATELY TOXIC, AND PROPYLENE CARBONATE IS CONSIDERED TO BE
NON-TOXIC BUT MODERATELY IRRITATING TO THE EYES. CIC10, IS
IRRITATING TO SKIN, EYES, AND MUCOUS MEMBRANES. CONTACT OF
ELECTROLYTE AND EXTRUDED LITHIUM WITH SKIN AND EYES SHOULD BE
AVOIDED.
Effects of Overexposure:DME MAY BE A REPRODUCTIVE HAZARD. LITHIUM CAN
CAUSE THERMAL & CHEMICAL BURNS ON CONTACT WITH SKIN.
Medical Cond Aggravated by Exposure:AN ACUTE EXPOSURE WILL GENERALLY
NOT AGGRAVATE ANY MEDICAL CONDITION.

First Aid

First Aid:IN CASE OF SKIN CONTACT WITH CONTENTS OF BATTERY, FLUSH
IMMEDIATELY WITH WATER. FOR EYE CONTACT, FLUSH WITH COPIOUS AMOUNT
OF WATER FOR 15 MINUTES. DO NOT INHALE VENTED MATERIAL. IF
IRRITATION PERSIST , GET MEDICAL HELP.

Fire Fighting

Flash Point:NONE PROVIDED BY
Lower Limits:NOT AVAILABL
Upper Limits:NOT AVAILABL
Extinguishing Media:WATER
Fire Fighting Procedures:IN CASE OF FIRE IN AN ADJACENT AREA, USE
WATER, CO2 OR DRY CHEMICAL EXTINGUISHERS IF CELL ARE PACKED IN
THEIR ORIGIONAL CONTAINERS SINCE THE FUEL OF THE FIRE IS BASICALLY
PAPER PRODUCTS. FOR BULK QUAN TITIES OF UNPACKAGED CELL US LITH-X
(GRAPHITE BASE). IN THIS CASE USE NO WATER.
Unusual Fire/Explosion Hazard:NONE PROVIDED BY MFR

Accidental Release

Spill Release Procedures:THE PREFERRED RESPONSE IS TO LEAVE AREA AND
ALLOW BATTERIES TO COOL AND VAPORS TO DISSIPATE. AVOID SKIN AND EYE
CONTACT OR INHALATION OF VAPORS. REMOVE SPILLED LIQUID WITH
ABSORBENT AND INCINERATE.

Handling

Handling and Storage Precautions:AVOID MECHANICAL OR ELECTRICAL ABUSE.
Other Precautions:BATTERIES MAY EXPLODE OR CAUSE BURN. IF DISASSEMBLED,
CRUSHED, RECHARGED OR EXPOSED TO FIRE OR HIGH TEMPERATURE. DO NOT
SHORT NOR INSTALL W/INCORRECT POLARITY.

Exposure Controls

Respiratory Protection:NOT NESCESSARY UNDER CONDITIONS OF NORMAL USE.
Ventilation:NOT NESCESSARY UNDER CONDITIONS OF NORMAL USE.
Protective Gloves:NOT NESCESSARY UNDER CONDITIONS OF NORMAL USE.
Eye Protection:NOT NESCESSARY UNDER CONDITIONS OF NORMAL USE.
Other Protective Equipment:NOT NESCESSARY UNDER CONDITIONS OF NORMAL
USE.
Supplemental Safety and Health
MANGANESE DIOXIDE LITHIUM PRIMARY BATTERIES. MODEL: COIN AND
CYLINDRICAL (SE) TYPE BATTERY.

Chemical Properties

HCC:Z6
NRC/State Lic Num:NONE
pH:UNKNON
Appearance and Odor:SEALED NON-RECHAGABLE BATTERY.

Stability

Stability Indicator/Materials to Avoid:YES
NONE PROVIDED BY MFR
Stability Condition to Avoid:DO NOT HEAT, DIASSEMBLE OR RECHARGE.
Conditions to Avoid Polymerization:WILL NOT OCCUR.

Disposal

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH APPROPRIATE
REGULATIONS. OPEN CELLS SHOULD BE TREATED AS HAZARDOUS WASTE.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.